Contact Us
Give Us A Call
+90 (242) 241 0305
+90 (543) 496 9535
Send Us Message
Visit Our Location
Bakü Türk Şehitleri Cad. Hüsnü Karakaş Mah. Nihat Bulut Apt. No:14/D Kepez/Antalya
A high-comfort steam room isn’t just pretty cladding; it needs the right vapour barrier, a properly sized steam generator, a sloped ceiling, balanced drainage and smart automation. For hotels, spa centres and villas, we handle end-to-end steam room construction and commissioning with aesthetics and durability in mind.
What Is a Steam Room? Key Benefits
- High humidity (≈95–100%) at 40–48°C for deep relaxation and skin/breathing comfort.
- Premium user experience with aromatherapy and LED lighting scenes.
- With the right generator and insulation, you get low energy use, quiet and stable operation.
Steam Room Construction — Design & Build Principles
- Vapour Barrier: Diffusion-resistant membrane with fully sealed transitions and penetrations.
- Sloped Ceiling: Dome or single-slope (≥2%) to prevent condensate drip.
- Drainage: Floor slope, trapped drain; washable, non-absorbent surfaces.
- Materials: Glass mosaic/porcelain with adhesives and grout rated for high humidity and heat.
- Seating Ergonomics: Radiused benches and coved corners for thermal comfort.
- Fresh Air & Venting: Controlled fresh-air intake with condensation management.
- Automation: Temperature/time programs, aroma dosing, LED scenes and safety interlocks.
Steam Room Packages — Quick Comparison
| Package | Contents | Recommended Use |
|---|---|---|
| Basic | Standard steam generator, manual aroma, IP65 LED, basic automation | Villas & boutique use |
| Pro | Automatic aroma dosing, stainless-steel generator, remote monitoring, anti-scale program | Spa centres & hotels |
| Enterprise | Parallel multi-generators, central automation, humidity sensor, maintenance SLA | Large hotels & resorts |
Generator Sizing — Practical Guide
Actual power depends on room volume, insulation quality, glass ratio and ceiling form. Use the ranges below as a guide:
| Room Volume (m³) | Recommended kW Range | Note |
|---|---|---|
| 4–6 m³ | 4.5–6 kW | Assumes good insulation |
| 6–10 m³ | 6–9 kW | Add ≈10% for large glass/cold corners |
| 10–15 m³ | 9–12 kW | Keep ≈15% reserve for heavy use |
For precise selection we survey the site and verify with manufacturer generator curves.
Equipment & Smart Features
- Steam Generator: Stainless housing, automatic blowdown, scale prevention and dry-run protection.
- Control Panel: Temperature/time settings, service reminders, fault alarm logs.
- Aroma Dosing: Constant-flow scent pump for consistent aromatherapy.
- Lighting: IP68 LED, colour scenes and dim control.
- Safety: Door magnet, hot-surface guards and anti-slip flooring.
Operations & Maintenance — Sample Plan
| Interval | Checks / Actions |
|---|---|
| Daily | Temperature/humidity tracking, surface cleaning, drain check |
| Weekly | Generator blowdown, line/filter cleaning, LED & door inspection |
| Monthly | Automation calibration, watertightness & safety tests |