Anatolia Pool & SPA

A high-comfort steam room isn’t just pretty cladding; it needs the right vapour barrier, a properly sized steam generator, a sloped ceiling, balanced drainage and smart automation. For hotels, spa centres and villas, we handle end-to-end steam room construction and commissioning with aesthetics and durability in mind.

What Is a Steam Room? Key Benefits

  • High humidity (≈95–100%) at 40–48°C for deep relaxation and skin/breathing comfort.
  • Premium user experience with aromatherapy and LED lighting scenes.
  • With the right generator and insulation, you get low energy use, quiet and stable operation.

Steam Room Construction — Design & Build Principles

  • Vapour Barrier: Diffusion-resistant membrane with fully sealed transitions and penetrations.
  • Sloped Ceiling: Dome or single-slope (≥2%) to prevent condensate drip.
  • Drainage: Floor slope, trapped drain; washable, non-absorbent surfaces.
  • Materials: Glass mosaic/porcelain with adhesives and grout rated for high humidity and heat.
  • Seating Ergonomics: Radiused benches and coved corners for thermal comfort.
  • Fresh Air & Venting: Controlled fresh-air intake with condensation management.
  • Automation: Temperature/time programs, aroma dosing, LED scenes and safety interlocks.

Steam Room Packages — Quick Comparison

Package Contents Recommended Use
Basic Standard steam generator, manual aroma, IP65 LED, basic automation Villas & boutique use
Pro Automatic aroma dosing, stainless-steel generator, remote monitoring, anti-scale program Spa centres & hotels
Enterprise Parallel multi-generators, central automation, humidity sensor, maintenance SLA Large hotels & resorts

Generator Sizing — Practical Guide

Actual power depends on room volume, insulation quality, glass ratio and ceiling form. Use the ranges below as a guide:

Room Volume (m³) Recommended kW Range Note
4–6 m³ 4.5–6 kW Assumes good insulation
6–10 m³ 6–9 kW Add ≈10% for large glass/cold corners
10–15 m³ 9–12 kW Keep ≈15% reserve for heavy use

For precise selection we survey the site and verify with manufacturer generator curves.

Equipment & Smart Features

  • Steam Generator: Stainless housing, automatic blowdown, scale prevention and dry-run protection.
  • Control Panel: Temperature/time settings, service reminders, fault alarm logs.
  • Aroma Dosing: Constant-flow scent pump for consistent aromatherapy.
  • Lighting: IP68 LED, colour scenes and dim control.
  • Safety: Door magnet, hot-surface guards and anti-slip flooring.

Operations & Maintenance — Sample Plan

Interval Checks / Actions
Daily Temperature/humidity tracking, surface cleaning, drain check
Weekly Generator blowdown, line/filter cleaning, LED & door inspection
Monthly Automation calibration, watertightness & safety tests